<?xml version="1.0" encoding="UTF-8"?><FDSNStationXML xmlns="http://www.fdsn.org/xml/station/1" schemaVersion="1.2"><Source>SeisComP</Source><Sender>BGR</Sender><Created>2026-07-26T14:53:26.516387Z</Created><Network code="BQ" startDate="1955-03-01T00:00:00Z" restrictedStatus="open"><Description>Bensberg Earthquake Network, University of Cologne</Description><Identifier type="DOI">10.7914/SN/BQ</Identifier><Station code="HILG" startDate="1998-07-30T00:00:00Z" restrictedStatus="open"><Latitude>50.292009</Latitude><Longitude>6.678694</Longitude><Elevation>504</Elevation><Site><Name>Hillesheim</Name><Country>Germany</Country></Site><CreationDate>1998-07-30T00:00:00Z</CreationDate><Channel code="EHE" startDate="1998-07-30T00:00:00Z" endDate="2002-12-18T12:00:00Z" restrictedStatus="closed" locationCode=""><Latitude>50.292009</Latitude><Longitude>6.678694</Longitude><Elevation>504</Elevation><Depth>1</Depth><Azimuth>90</Azimuth><Dip>0</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="Mark_L-4-3D_384_EHE_PaZG60.9"><Description>L-4C, 1 Hz, 51.5 V/m/s, Rc=500 Ohms, Rs=810 Ohms-G</Description><Manufacturer>Mark Products</Manufacturer><Model>L-4-3D</Model></Sensor><DataLogger resourceId="Unknown/Workstation_FR125_G47600_ResG100"><Type>Unknown</Type><Manufacturer>Royal Observatory of Belgium</Manufacturer><Model>Unknown</Model></DataLogger><Response><InstrumentSensitivity><Value>289884000</Value><Frequency>5</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="EHN" startDate="1998-07-30T00:00:00Z" endDate="2002-12-18T12:00:00Z" restrictedStatus="closed" locationCode=""><Latitude>50.292009</Latitude><Longitude>6.678694</Longitude><Elevation>504</Elevation><Depth>1</Depth><Azimuth>0</Azimuth><Dip>0</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="Mark_L-4-3D_384_EHN_PaZG53.1"><Description>L-4C, 1 Hz, 51.5 V/m/s, Rc=500 Ohms, Rs=810 Ohms-G</Description><Manufacturer>Mark Products</Manufacturer><Model>L-4-3D</Model></Sensor><DataLogger resourceId="Unknown/Workstation_FR125_G47600_ResG100"><Type>Unknown</Type><Manufacturer>Royal Observatory of Belgium</Manufacturer><Model>Unknown</Model></DataLogger><Response><InstrumentSensitivity><Value>252756000</Value><Frequency>5</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="EHZ" startDate="1998-07-30T00:00:00Z" endDate="2002-12-18T12:00:00Z" restrictedStatus="closed" locationCode=""><Latitude>50.292009</Latitude><Longitude>6.678694</Longitude><Elevation>504</Elevation><Depth>1</Depth><Azimuth>0</Azimuth><Dip>-90</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="Mark_L-4-3D_384_EHZ_PaZG44.6"><Description>L-4C, 1 Hz, 51.5 V/m/s, Rc=500 Ohms, Rs=810 Ohms-G</Description><Manufacturer>Mark Products</Manufacturer><Model>L-4-3D</Model></Sensor><DataLogger resourceId="Unknown/Workstation_FR125_G47600_ResG100"><Type>Unknown</Type><Manufacturer>Royal Observatory of Belgium</Manufacturer><Model>Unknown</Model></DataLogger><Response><InstrumentSensitivity><Value>212296000</Value><Frequency>5</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="EHE" startDate="2002-12-18T12:00:00Z" endDate="2003-04-15T00:00:00Z" restrictedStatus="open" locationCode=""><Latitude>50.292009</Latitude><Longitude>6.678694</Longitude><Elevation>504</Elevation><Depth>1</Depth><Azimuth>90</Azimuth><Dip>0</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="Mark_L-4-3D_384_EHE_PaZG60.8"><Description>L-4C, 1 Hz, 51.5 V/m/s, Rc=500 Ohms, Rs=810 Ohms-G</Description><Manufacturer>Mark Products</Manufacturer><Model>L-4-3D</Model></Sensor><DataLogger resourceId="DSM/Nanoserver_FR125_G393000_ResG104.7"><Type>AMP4CH PAR4CH</Type><Manufacturer>SymRes</Manufacturer><Model>AMP4CH PAR4CH</Model></DataLogger><Response><InstrumentSensitivity><Value>2502054307</Value><Frequency>5</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="EHN" startDate="2002-12-18T12:00:00Z" endDate="2003-04-15T00:00:00Z" restrictedStatus="open" locationCode=""><Latitude>50.292009</Latitude><Longitude>6.678694</Longitude><Elevation>504</Elevation><Depth>1</Depth><Azimuth>0</Azimuth><Dip>0</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="Mark_L-4-3D_384_EHN_PaZG53.1"><Description>L-4C, 1 Hz, 51.5 V/m/s, Rc=500 Ohms, Rs=810 Ohms-G</Description><Manufacturer>Mark Products</Manufacturer><Model>L-4-3D</Model></Sensor><DataLogger resourceId="DSM/Nanoserver_FR125_G393000_ResG104.7"><Type>AMP4CH PAR4CH</Type><Manufacturer>SymRes</Manufacturer><Model>AMP4CH PAR4CH</Model></DataLogger><Response><InstrumentSensitivity><Value>2185182298</Value><Frequency>5</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="EHZ" startDate="2002-12-18T12:00:00Z" endDate="2003-04-15T00:00:00Z" restrictedStatus="open" locationCode=""><Latitude>50.292009</Latitude><Longitude>6.678694</Longitude><Elevation>504</Elevation><Depth>1</Depth><Azimuth>0</Azimuth><Dip>-90</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="Mark_L-4-3D_384_EHZ_PaZG44.6"><Description>L-4C, 1 Hz, 51.5 V/m/s, Rc=500 Ohms, Rs=810 Ohms-G</Description><Manufacturer>Mark Products</Manufacturer><Model>L-4-3D</Model></Sensor><DataLogger resourceId="DSM/Nanoserver_FR125_G393000_ResG104.7"><Type>AMP4CH PAR4CH</Type><Manufacturer>SymRes</Manufacturer><Model>AMP4CH PAR4CH</Model></DataLogger><Response><InstrumentSensitivity><Value>1835388521</Value><Frequency>5</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="EHE" startDate="2003-04-15T00:00:00Z" endDate="2022-03-31T09:30:00Z" restrictedStatus="open" locationCode=""><Latitude>50.292009</Latitude><Longitude>6.678694</Longitude><Elevation>504</Elevation><Depth>1</Depth><Azimuth>90</Azimuth><Dip>0</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="Mark_L-4-3D_2175_8949_EHE_PaZG141"><Description>L-4C, 1 Hz, 51.5 V/m/s, Rc=500 Ohms, Rs=810 Ohms-G</Description><Manufacturer>Mark Products</Manufacturer><Model>L-4-3D</Model></Sensor><DataLogger resourceId="DSM/Nanoserver_FR125_G393000_ResG104.7"><Type>AMP4CH PAR4CH</Type><Manufacturer>SymRes</Manufacturer><Model>AMP4CH PAR4CH</Model></DataLogger><Response><InstrumentSensitivity><Value>5802461469</Value><Frequency>5</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="EHN" startDate="2003-04-15T00:00:00Z" endDate="2022-03-31T09:30:00Z" restrictedStatus="open" locationCode=""><Latitude>50.292009</Latitude><Longitude>6.678694</Longitude><Elevation>504</Elevation><Depth>1</Depth><Azimuth>0</Azimuth><Dip>0</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="Mark_L-4-3D_2175_8948_EHN_PaZG166"><Description>L-4C, 1 Hz, 51.5 V/m/s, Rc=500 Ohms, Rs=810 Ohms-G</Description><Manufacturer>Mark Products</Manufacturer><Model>L-4-3D</Model></Sensor><DataLogger resourceId="DSM/Nanoserver_FR125_G393000_ResG104.7"><Type>AMP4CH PAR4CH</Type><Manufacturer>SymRes</Manufacturer><Model>AMP4CH PAR4CH</Model></DataLogger><Response><InstrumentSensitivity><Value>6831266694</Value><Frequency>5</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="EHZ" startDate="2003-04-15T00:00:00Z" endDate="2022-03-31T09:30:00Z" restrictedStatus="open" locationCode=""><Latitude>50.292009</Latitude><Longitude>6.678694</Longitude><Elevation>504</Elevation><Depth>1</Depth><Azimuth>0</Azimuth><Dip>-90</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="Mark_L-4-3D_2175_8947_EHZ_PaZG140"><Description>L-4C, 1 Hz, 51.5 V/m/s, Rc=500 Ohms, Rs=810 Ohms-G</Description><Manufacturer>Mark Products</Manufacturer><Model>L-4-3D</Model></Sensor><DataLogger resourceId="DSM/Nanoserver_FR125_G393000_ResG104.7"><Type>AMP4CH PAR4CH</Type><Manufacturer>SymRes</Manufacturer><Model>AMP4CH PAR4CH</Model></DataLogger><Response><InstrumentSensitivity><Value>5761309260</Value><Frequency>5</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="HHE" startDate="2022-03-31T15:00:00Z" endDate="2026-07-19T00:00:00Z" restrictedStatus="open" locationCode=""><Latitude>50.292009</Latitude><Longitude>6.678694</Longitude><Elevation>504</Elevation><Depth>1</Depth><Azimuth>90</Azimuth><Dip>0</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><Sensor resourceId="NRL/Nanometrics/TrilliumCompact120_SG754_LP120_STgroundVel"><Manufacturer>Nanometrics</Manufacturer><Model>Trillium Compact 120</Model></Sensor><DataLogger resourceId="NRL/Nanometrics/Centaur_FV40Vpp_FR125_DFOff_FPLinear"><Type>Centaur CTR4-xS</Type><Manufacturer>Nanometrics</Manufacturer><Model>Centaur CTR4-xS</Model></DataLogger><Response><InstrumentSensitivity><Value>301720000</Value><Frequency>1</Frequency><InputUnits><Name>m/s</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="HHN" startDate="2022-03-31T15:00:00Z" endDate="2026-07-19T00:00:00Z" restrictedStatus="open" locationCode=""><Latitude>50.292009</Latitude><Longitude>6.678694</Longitude><Elevation>504</Elevation><Depth>1</Depth><Azimuth>0</Azimuth><Dip>0</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><Sensor resourceId="NRL/Nanometrics/TrilliumCompact120_SG754_LP120_STgroundVel"><Manufacturer>Nanometrics</Manufacturer><Model>Trillium Compact 120</Model></Sensor><DataLogger resourceId="NRL/Nanometrics/Centaur_FV40Vpp_FR125_DFOff_FPLinear"><Type>Centaur CTR4-xS</Type><Manufacturer>Nanometrics</Manufacturer><Model>Centaur CTR4-xS</Model></DataLogger><Response><InstrumentSensitivity><Value>301720000</Value><Frequency>1</Frequency><InputUnits><Name>m/s</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="HHZ" startDate="2022-03-31T15:00:00Z" endDate="2026-07-19T00:00:00Z" restrictedStatus="open" locationCode=""><Latitude>50.292009</Latitude><Longitude>6.678694</Longitude><Elevation>504</Elevation><Depth>1</Depth><Azimuth>0</Azimuth><Dip>-90</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><Sensor resourceId="NRL/Nanometrics/TrilliumCompact120_SG754_LP120_STgroundVel"><Manufacturer>Nanometrics</Manufacturer><Model>Trillium Compact 120</Model></Sensor><DataLogger resourceId="NRL/Nanometrics/Centaur_FV40Vpp_FR125_DFOff_FPLinear"><Type>Centaur CTR4-xS</Type><Manufacturer>Nanometrics</Manufacturer><Model>Centaur CTR4-xS</Model></DataLogger><Response><InstrumentSensitivity><Value>301720000</Value><Frequency>1</Frequency><InputUnits><Name>m/s</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel></Station></Network></FDSNStationXML>
