<?xml version="1.0" encoding="UTF-8"?><FDSNStationXML xmlns="http://www.fdsn.org/xml/station/1" schemaVersion="1.2"><Source>SeisComP</Source><Sender>BGR</Sender><Created>2026-07-26T15:02:12.947829Z</Created><Network code="BQ" startDate="1955-03-01T00:00:00Z" restrictedStatus="open"><Description>Bensberg Earthquake Network, University of Cologne</Description><Identifier type="DOI">10.7914/SN/BQ</Identifier><Station code="BGG" startDate="1977-01-01T00:00:00Z" restrictedStatus="open"><Latitude>50.204875</Latitude><Longitude>7.336364</Longitude><Elevation>132</Elevation><Site><Name>Eltz Castle</Name><Country>Germany</Country></Site><CreationDate>1977-01-01T00:00:00Z</CreationDate><Channel code="EHN" startDate="1998-08-10T12:00:00Z" endDate="2002-12-11T12:00:00Z" restrictedStatus="open" locationCode=""><Latitude>50.204875</Latitude><Longitude>7.336364</Longitude><Elevation>132</Elevation><Depth>1</Depth><Azimuth>0</Azimuth><Dip>0</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="Geotech_S-13_1366_PaZG440"><Description>S-13, 1 Hz, 629 V/m/s, 3600 ohm coil-Generic Datal</Description><Manufacturer>Geotech</Manufacturer><Model>S-13</Model></Sensor><DataLogger resourceId="Unknown/Workstation_FR125_G47600_ResG10"><Type>Unknown</Type><Manufacturer>Royal Observatory of Belgium</Manufacturer><Model>Unknown</Model></DataLogger><Response><InstrumentSensitivity><Value>209440000</Value><Frequency>5</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="EHE" startDate="1998-08-10T12:00:00Z" endDate="2002-12-11T12:00:00Z" restrictedStatus="open" locationCode=""><Latitude>50.204875</Latitude><Longitude>7.336364</Longitude><Elevation>132</Elevation><Depth>1</Depth><Azimuth>90</Azimuth><Dip>0</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="Geotech_S-13_1367_PaZG460"><Description>S-13, 1 Hz, 629 V/m/s, 3600 ohm coil-Generic Datal</Description><Manufacturer>Geotech</Manufacturer><Model>S-13</Model></Sensor><DataLogger resourceId="Unknown/Workstation_FR125_G47600_ResG10"><Type>Unknown</Type><Manufacturer>Royal Observatory of Belgium</Manufacturer><Model>Unknown</Model></DataLogger><Response><InstrumentSensitivity><Value>218960000</Value><Frequency>5</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="EHZ" startDate="1998-08-10T12:00:00Z" endDate="2002-12-11T12:00:00Z" restrictedStatus="open" locationCode=""><Latitude>50.204875</Latitude><Longitude>7.336364</Longitude><Elevation>132</Elevation><Depth>1</Depth><Azimuth>0</Azimuth><Dip>-90</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="Geotech_S-13_1365_PaZG507"><Description>S-13, 1 Hz, 629 V/m/s, 3600 ohm coil-Generic Datal</Description><Manufacturer>Geotech</Manufacturer><Model>S-13</Model></Sensor><DataLogger resourceId="Unknown/Workstation_FR125_G47600_ResG10"><Type>Unknown</Type><Manufacturer>Royal Observatory of Belgium</Manufacturer><Model>Unknown</Model></DataLogger><Response><InstrumentSensitivity><Value>241332000</Value><Frequency>5</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="EHE" startDate="2002-12-11T12:00:00Z" endDate="2005-04-07T00:00:00Z" restrictedStatus="open" locationCode=""><Latitude>50.204875</Latitude><Longitude>7.336364</Longitude><Elevation>132</Elevation><Depth>1</Depth><Azimuth>90</Azimuth><Dip>0</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="Geotech_S-13_1367_PaZG460"><Description>S-13, 1 Hz, 629 V/m/s, 3600 ohm coil-Generic Datal</Description><Manufacturer>Geotech</Manufacturer><Model>S-13</Model></Sensor><DataLogger resourceId="DSM/Nanoserver_FR125_G393000_ResG104.7"><Type>AMP4CH PAR4CH</Type><Manufacturer>SymRes</Manufacturer><Model>AMP4CH PAR4CH</Model></DataLogger><Response><InstrumentSensitivity><Value>1.893001614e+10</Value><Frequency>5</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="EHN" startDate="2002-12-11T12:00:00Z" endDate="2005-04-07T00:00:00Z" restrictedStatus="open" locationCode=""><Latitude>50.204875</Latitude><Longitude>7.336364</Longitude><Elevation>132</Elevation><Depth>1</Depth><Azimuth>0</Azimuth><Dip>0</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="Geotech_S-13_1366_PaZG440"><Description>S-13, 1 Hz, 629 V/m/s, 3600 ohm coil-Generic Datal</Description><Manufacturer>Geotech</Manufacturer><Model>S-13</Model></Sensor><DataLogger resourceId="DSM/Nanoserver_FR125_G393000_ResG104.7"><Type>AMP4CH PAR4CH</Type><Manufacturer>SymRes</Manufacturer><Model>AMP4CH PAR4CH</Model></DataLogger><Response><InstrumentSensitivity><Value>1.810697196e+10</Value><Frequency>5</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="EHZ" startDate="2002-12-11T12:00:00Z" endDate="2005-04-07T00:00:00Z" restrictedStatus="open" locationCode=""><Latitude>50.204875</Latitude><Longitude>7.336364</Longitude><Elevation>132</Elevation><Depth>1</Depth><Azimuth>0</Azimuth><Dip>-90</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="Geotech_S-13_1365_PaZG507"><Description>S-13, 1 Hz, 629 V/m/s, 3600 ohm coil-Generic Datal</Description><Manufacturer>Geotech</Manufacturer><Model>S-13</Model></Sensor><DataLogger resourceId="DSM/Nanoserver_FR125_G393000_ResG104.7"><Type>AMP4CH PAR4CH</Type><Manufacturer>SymRes</Manufacturer><Model>AMP4CH PAR4CH</Model></DataLogger><Response><InstrumentSensitivity><Value>2.086416996e+10</Value><Frequency>5</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="EHE" startDate="2005-04-07T00:00:00Z" endDate="2022-10-12T09:30:00Z" restrictedStatus="open" locationCode=""><Latitude>50.204875</Latitude><Longitude>7.336364</Longitude><Elevation>132</Elevation><Depth>1</Depth><Azimuth>90</Azimuth><Dip>0</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="Geotech_S-13_1367_PaZG460"><Description>S-13, 1 Hz, 629 V/m/s, 3600 ohm coil-Generic Datal</Description><Manufacturer>Geotech</Manufacturer><Model>S-13</Model></Sensor><DataLogger resourceId="DSM/Nanoserver_FR125_G393000_ResG10"><Type>AMP4CH PAR4CH</Type><Manufacturer>SymRes</Manufacturer><Model>AMP4CH PAR4CH</Model></DataLogger><Response><InstrumentSensitivity><Value>1807800000</Value><Frequency>5</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="EHN" startDate="2005-04-07T00:00:00Z" endDate="2022-10-12T09:30:00Z" restrictedStatus="open" locationCode=""><Latitude>50.204875</Latitude><Longitude>7.336364</Longitude><Elevation>132</Elevation><Depth>1</Depth><Azimuth>0</Azimuth><Dip>0</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="Geotech_S-13_1366_PaZG440"><Description>S-13, 1 Hz, 629 V/m/s, 3600 ohm coil-Generic Datal</Description><Manufacturer>Geotech</Manufacturer><Model>S-13</Model></Sensor><DataLogger resourceId="DSM/Nanoserver_FR125_G393000_ResG10"><Type>AMP4CH PAR4CH</Type><Manufacturer>SymRes</Manufacturer><Model>AMP4CH PAR4CH</Model></DataLogger><Response><InstrumentSensitivity><Value>1729200000</Value><Frequency>5</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="EHZ" startDate="2005-04-07T00:00:00Z" endDate="2022-10-12T09:30:00Z" restrictedStatus="open" locationCode=""><Latitude>50.204875</Latitude><Longitude>7.336364</Longitude><Elevation>132</Elevation><Depth>1</Depth><Azimuth>0</Azimuth><Dip>-90</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><ClockDrift>0</ClockDrift><Sensor resourceId="Geotech_S-13_1365_PaZG507"><Description>S-13, 1 Hz, 629 V/m/s, 3600 ohm coil-Generic Datal</Description><Manufacturer>Geotech</Manufacturer><Model>S-13</Model></Sensor><DataLogger resourceId="DSM/Nanoserver_FR125_G393000_ResG10"><Type>AMP4CH PAR4CH</Type><Manufacturer>SymRes</Manufacturer><Model>AMP4CH PAR4CH</Model></DataLogger><Response><InstrumentSensitivity><Value>1992510000</Value><Frequency>5</Frequency><InputUnits><Name>M/S</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="HHN" startDate="2022-05-18T09:30:00Z" endDate="2026-07-19T00:00:00Z" restrictedStatus="open" locationCode=""><Latitude>50.204875</Latitude><Longitude>7.336364</Longitude><Elevation>132</Elevation><Depth>1</Depth><Azimuth>0</Azimuth><Dip>0</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><Sensor resourceId="NRL/Nanometrics_TrilliumHorizon120_LP120_SG1203_STgroundVel"><Description>Nanometrics; TrilliumHorizon120; Long-Period_Corner 120 s; Sensitivity 1203 V/m/s; Sensor_Type groundVel</Description><Manufacturer>Nanometrics</Manufacturer><Model>TrilliumHorizon120</Model></Sensor><DataLogger resourceId="NRL/Nanometrics/Centaur_FV40Vpp_FR125_DFOff_FPLinear"><Type>Centaur CTR4-xS</Type><Manufacturer>Nanometrics</Manufacturer><Model>Centaur CTR4-xS</Model></DataLogger><Response><InstrumentSensitivity><Value>481000000</Value><Frequency>1</Frequency><InputUnits><Name>m/s</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="HHZ" startDate="2022-05-18T09:30:00Z" endDate="2026-07-19T00:00:00Z" restrictedStatus="open" locationCode=""><Latitude>50.204875</Latitude><Longitude>7.336364</Longitude><Elevation>132</Elevation><Depth>1</Depth><Azimuth>0</Azimuth><Dip>-90</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><Sensor resourceId="NRL/Nanometrics_TrilliumHorizon120_LP120_SG1203_STgroundVel"><Description>Nanometrics; TrilliumHorizon120; Long-Period_Corner 120 s; Sensitivity 1203 V/m/s; Sensor_Type groundVel</Description><Manufacturer>Nanometrics</Manufacturer><Model>TrilliumHorizon120</Model></Sensor><DataLogger resourceId="NRL/Nanometrics/Centaur_FV40Vpp_FR125_DFOff_FPLinear"><Type>Centaur CTR4-xS</Type><Manufacturer>Nanometrics</Manufacturer><Model>Centaur CTR4-xS</Model></DataLogger><Response><InstrumentSensitivity><Value>481000000</Value><Frequency>1</Frequency><InputUnits><Name>m/s</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel><Channel code="HHE" startDate="2022-05-18T09:30:00Z" endDate="2026-07-19T00:00:00Z" restrictedStatus="open" locationCode=""><Latitude>50.204875</Latitude><Longitude>7.336364</Longitude><Elevation>132</Elevation><Depth>1</Depth><Azimuth>90</Azimuth><Dip>0</Dip><SampleRate>125</SampleRate><SampleRateRatio><NumberSamples>125</NumberSamples><NumberSeconds>1</NumberSeconds></SampleRateRatio><Sensor resourceId="NRL/Nanometrics_TrilliumHorizon120_LP120_SG1203_STgroundVel"><Description>Nanometrics; TrilliumHorizon120; Long-Period_Corner 120 s; Sensitivity 1203 V/m/s; Sensor_Type groundVel</Description><Manufacturer>Nanometrics</Manufacturer><Model>TrilliumHorizon120</Model></Sensor><DataLogger resourceId="NRL/Nanometrics/Centaur_FV40Vpp_FR125_DFOff_FPLinear"><Type>Centaur CTR4-xS</Type><Manufacturer>Nanometrics</Manufacturer><Model>Centaur CTR4-xS</Model></DataLogger><Response><InstrumentSensitivity><Value>481000000</Value><Frequency>1</Frequency><InputUnits><Name>m/s</Name></InputUnits><OutputUnits><Name/></OutputUnits></InstrumentSensitivity></Response></Channel></Station></Network></FDSNStationXML>
